Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	45
Date	08/07/14
Start Time	16:36:13
Diameter Midpoint
 11.3	618535
 11.8	444370
 12.2	364894
 12.6	321049
 13.1	270188
 13.6	228324
 14.1	199083
 14.6	176939
 15.1	155025
 15.7	138938
 16.3	117641
 16.8	96631
 17.5	78466.2
 18.1	64109.4
 18.8	51165.9
 19.5	43151.7
 20.2	36499.3
 20.9	32398.7
 21.7	30158.2
 22.5	29559.6
 23.3	29015.2
 24.1	30011.6
 25.0	32926.7
 25.9	35040.6
 26.9	36115.9
 27.9	35803.9
 28.9	37870.1
 30.0	37960.4
 31.1	35954.2
 32.2	36304.8
 33.4	37652.4
 34.6	39055.9
 35.9	39593.2
 37.2	37531.9
 38.5	36190.9
 40.0	34549.3
 41.4	34309.7
 42.9	33770.1
 44.5	31934.2
 46.1	27942.4
 47.8	23048.6
 49.6	19654.3
 51.4	17672.9
 53.3	14652.3
 55.2	12606.2
 57.3	10345
 59.4	8687.04
 61.5	7187.36
 63.8	6253.33
 66.1	4928.9
 68.5	3934.45
 71.0	3183.34
 73.7	2530.68
 76.4	2263.06
 79.1	1821.68
 82.0	1466.53
 85.1	1216.56
 88.2	1036.08
 91.4	880.111
 94.7	849.969
 98.2	823.451
101.8	847.44
105.5	696.422
109.4	654.206
113.4	595.251
117.6	448.559
121.9	329.809
126.3	264.149
131.0	215.789
135.8	207.848
140.7	140.623
145.9	140.764
151.2	141.505
156.8	144.691
162.5	100.917
168.5	94.6713
174.7	63.7141
181.1	63.7478
187.7	36.0777
194.6	50.8068
201.7	45.5278
209.1	30.802
216.7	37.1154
224.7	26.1957
232.9	13.2882
241.4	14.8387
250.3	10.0579
259.5	14.4372
269.0	13.693
278.8	7.06323
289.0	9.50688
299.6	15.3784
310.6	3.45864
322.0	12.0413
333.8	6.29365
346.0	9.99514
358.7	7.0945
371.8	10.9806
385.4	4.47175
399.5	0
414.2	0
429.4	0.404177
445.1	6.72865
461.4	1.21511
478.3	8.66443
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.6847
High Voltage	9952.69
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	13.6682
Mean(nm)	18.4728
Geo. Mean(nm)	16.3761
Mode(nm)	11.3419
Geo. Std. Dev.	1.55267
Total Concentration(#/cm)	4.34725e+006
Comment	